Design and Development of a New Tactile Stimulator

dc.authoridAYDIN, Nizamettin/0000-0003-0022-2247
dc.authorscopusid57202990663
dc.authorscopusid57038925900
dc.authorscopusid7005593269
dc.authorwosidAYDIN, Nizamettin/AAZ-6030-2020
dc.authorwosidlevent, vecdi/T-8847-2019
dc.authorwosidkazma, coşkun/AAP-7016-2020
dc.contributor.authorLevent, Vecdi Emre
dc.contributor.authorLevent, Vecdi Emre
dc.contributor.authorAydin, Nizamettin
dc.contributor.otherBilgisayar Mühendisliği Bölümü
dc.date.accessioned2025-01-11T13:01:32Z
dc.date.available2025-01-11T13:01:32Z
dc.date.issued2019
dc.departmentFenerbahçe Universityen_US
dc.department-temp[Kazma, Coskun; Aydin, Nizamettin] Yildiz Tech Univ, Dept Comp Engn, Istanbul, Turkey; [Levent, Vecdi Emre] Fenerbahce Univ, Dept Comp Engn, Istanbul, Turkeyen_US
dc.descriptionAYDIN, Nizamettin/0000-0003-0022-2247en_US
dc.description.abstractWe have designed and implement a tactile stimulator to obtain information from the central nervous system. Our system consists of two main components. The first one is tactile stimulator, which was designed to stimulate index and middle finger tips, stimulating mechanoreceptors according to the test protocol. Second one is a personal computer running a desktop software for the implementation of test protocols. The flow is as follows; the subjects are asked the question of the test protocol through the personal computer. The parameters are then transmitted to the embedded board on the machine. The embedded board drives step motors to apply the relevant test parameters. The desktop software expects the individual to answer the question using the right or the left mouse button of the computer mouse. After answering the relevant question, the test proceeds to the next step. According to the test protocol, the stimulation process of the mechanoreceptors located at the index and middle finger tips must start and terminate at the same time. From this perspective, the embedded board with 3 18F46K22 PIC microcontrollers produces 2 square wave signals with different frequencies and amplitudes at the same time. The embedded system card developed with the PIC microcontroller is also developed with FPGA. The system has also been tested on 24 blue and white collar employees and a significant result has been obtained.en_US
dc.description.woscitationindexConference Proceedings Citation Index - Science
dc.identifier.citation1
dc.identifier.doi10.1109/AHS.2019.00004
dc.identifier.endpage60en_US
dc.identifier.isbn9781728146508
dc.identifier.issn1939-7003
dc.identifier.scopus2-s2.0-85071579274
dc.identifier.scopusqualityN/A
dc.identifier.startpage55en_US
dc.identifier.urihttps://doi.org/10.1109/AHS.2019.00004
dc.identifier.urihttps://hdl.handle.net/20.500.14627/142
dc.identifier.wosWOS:000494726000008
dc.identifier.wosqualityN/A
dc.language.isoenen_US
dc.publisherIeeeen_US
dc.relation.ispartofNASA/ESA Conference on Adaptive Hardware and Systems (AHS) -- JUL 22-24, 2019 -- Univ Essex, Colchester, ENGLANDen_US
dc.relation.ispartofseriesNASA/ESA Conference on Adaptive Hardware and Systems
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectParallel Square Wave Generationen_US
dc.subjectTactile Stimulatoren_US
dc.subjectFpgaen_US
dc.titleDesign and Development of a New Tactile Stimulatoren_US
dc.typeConference Objecten_US
dspace.entity.typePublication
relation.isAuthorOfPublication8152bbc4-3dea-4808-b2b9-69399f11ec0b
relation.isAuthorOfPublication.latestForDiscovery8152bbc4-3dea-4808-b2b9-69399f11ec0b
relation.isOrgUnitOfPublication85e04a04-fb9d-4894-961f-e92f27bb6cb6
relation.isOrgUnitOfPublication.latestForDiscovery85e04a04-fb9d-4894-961f-e92f27bb6cb6

Files