Design and Development of a New Tactile Stimulator

dc.authorid AYDIN, Nizamettin/0000-0003-0022-2247
dc.authorscopusid 57202990663
dc.authorscopusid 57038925900
dc.authorscopusid 7005593269
dc.authorwosid AYDIN, Nizamettin/AAZ-6030-2020
dc.authorwosid levent, vecdi/T-8847-2019
dc.authorwosid kazma, coşkun/AAP-7016-2020
dc.contributor.author Levent, Vecdi Emre
dc.contributor.author Levent, Vecdi Emre
dc.contributor.author Aydin, Nizamettin
dc.contributor.other Bilgisayar Mühendisliği Bölümü
dc.date.accessioned 2025-01-11T13:01:32Z
dc.date.available 2025-01-11T13:01:32Z
dc.date.issued 2019
dc.department Fenerbahçe University en_US
dc.department-temp [Kazma, Coskun; Aydin, Nizamettin] Yildiz Tech Univ, Dept Comp Engn, Istanbul, Turkey; [Levent, Vecdi Emre] Fenerbahce Univ, Dept Comp Engn, Istanbul, Turkey en_US
dc.description AYDIN, Nizamettin/0000-0003-0022-2247 en_US
dc.description.abstract We have designed and implement a tactile stimulator to obtain information from the central nervous system. Our system consists of two main components. The first one is tactile stimulator, which was designed to stimulate index and middle finger tips, stimulating mechanoreceptors according to the test protocol. Second one is a personal computer running a desktop software for the implementation of test protocols. The flow is as follows; the subjects are asked the question of the test protocol through the personal computer. The parameters are then transmitted to the embedded board on the machine. The embedded board drives step motors to apply the relevant test parameters. The desktop software expects the individual to answer the question using the right or the left mouse button of the computer mouse. After answering the relevant question, the test proceeds to the next step. According to the test protocol, the stimulation process of the mechanoreceptors located at the index and middle finger tips must start and terminate at the same time. From this perspective, the embedded board with 3 18F46K22 PIC microcontrollers produces 2 square wave signals with different frequencies and amplitudes at the same time. The embedded system card developed with the PIC microcontroller is also developed with FPGA. The system has also been tested on 24 blue and white collar employees and a significant result has been obtained. en_US
dc.description.woscitationindex Conference Proceedings Citation Index - Science
dc.identifier.citation 1
dc.identifier.doi 10.1109/AHS.2019.00004
dc.identifier.endpage 60 en_US
dc.identifier.isbn 9781728146508
dc.identifier.issn 1939-7003
dc.identifier.scopus 2-s2.0-85071579274
dc.identifier.scopusquality N/A
dc.identifier.startpage 55 en_US
dc.identifier.uri https://doi.org/10.1109/AHS.2019.00004
dc.identifier.uri https://hdl.handle.net/20.500.14627/142
dc.identifier.wos WOS:000494726000008
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.publisher Ieee en_US
dc.relation.ispartof NASA/ESA Conference on Adaptive Hardware and Systems (AHS) -- JUL 22-24, 2019 -- Univ Essex, Colchester, ENGLAND en_US
dc.relation.ispartofseries NASA/ESA Conference on Adaptive Hardware and Systems
dc.relation.publicationcategory Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 1
dc.subject Parallel Square Wave Generation en_US
dc.subject Tactile Stimulator en_US
dc.subject Fpga en_US
dc.title Design and Development of a New Tactile Stimulator en_US
dc.type Conference Object en_US
dc.wos.citedbyCount 1
dspace.entity.type Publication
relation.isAuthorOfPublication 8152bbc4-3dea-4808-b2b9-69399f11ec0b
relation.isAuthorOfPublication.latestForDiscovery 8152bbc4-3dea-4808-b2b9-69399f11ec0b
relation.isOrgUnitOfPublication 85e04a04-fb9d-4894-961f-e92f27bb6cb6
relation.isOrgUnitOfPublication.latestForDiscovery 85e04a04-fb9d-4894-961f-e92f27bb6cb6

Files