Parametric Trigger Signal Generation With Microcontroller and Fpga Based Architectures

dc.authorwosid levent, vecdi/T-8847-2019
dc.authorwosid kazma, coşkun/AAP-7016-2020
dc.authorwosid AYDIN, Nizamettin/AAZ-6030-2020
dc.contributor.author Levent, Vecdi Emre
dc.contributor.author Levent, Vecdi Emre
dc.contributor.author Aydin, Nizamettin
dc.contributor.other Bilgisayar Mühendisliği Bölümü
dc.date.accessioned 2025-01-11T13:01:32Z
dc.date.available 2025-01-11T13:01:32Z
dc.date.issued 2019
dc.department Fenerbahçe University en_US
dc.department-temp [Kazma, Coskun; Aydin, Nizamettin] Yildiz Tekn Univ, Bilgisayar Muhendisligi Bolumu, Istanbul, Turkey; [Levent, Vecdi Emre] Fenerbahce Univ, Bilgisayar Muhendisligi Bolumu, Istanbul, Turkey en_US
dc.description.abstract A new system to obtain information from the central nervous system has been developed. Our system consists of two main components. The first of these components is the machine, which is located on the index and middle finger tips, stimulating mechanoreceptors according to the test protocol. The other is a personal computer running a desktop software for the implementation of test protocols. The flow is as follows. The subjects are asked the question of the test protocol through the personal computer. The parameters are then transmitted to the embedded system board on the machine. The embedded system board takes step motors to apply the relevant test parameters. The desktop software expects the subject to answer the question using the right and/or the left mouse button of the computer mouse. After answering the relevant question, the test proceeds to the next step. According to the test protocol, the stimulation process of the mechanoreceptors located at the index and middle finger tips must start and terminate at the same time. From this perspective, the embedded system board with 3 18F46K22 PIC microcontrollers produces 2 square wave signals with different frequencies and amplitudes simultaneously. The embedded system card developed with the PIC microcontroller is also implemented on an FPGA. The system has also been tested on 24 blue- and white-collar employees and a significant result has been obtained. en_US
dc.description.woscitationindex Conference Proceedings Citation Index - Science
dc.identifier.citation 0
dc.identifier.endpage 144 en_US
dc.identifier.isbn 9781728139647
dc.identifier.scopusquality N/A
dc.identifier.startpage 140 en_US
dc.identifier.uri https://hdl.handle.net/20.500.14627/141
dc.identifier.wos WOS:000609879900027
dc.identifier.wosquality N/A
dc.language.iso tr en_US
dc.publisher Ieee en_US
dc.relation.ispartof 4th International Conference on Computer Science and Engineering (UBMK) -- SEP 11-15, 2019 -- Samsun, TURKEY en_US
dc.relation.publicationcategory Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Parallel Square Wave Generation en_US
dc.subject Tactile Stimulator en_US
dc.subject Fpga en_US
dc.title Parametric Trigger Signal Generation With Microcontroller and Fpga Based Architectures en_US
dc.type Conference Object en_US
dc.wos.citedbyCount 0
dspace.entity.type Publication
relation.isAuthorOfPublication 8152bbc4-3dea-4808-b2b9-69399f11ec0b
relation.isAuthorOfPublication.latestForDiscovery 8152bbc4-3dea-4808-b2b9-69399f11ec0b
relation.isOrgUnitOfPublication 85e04a04-fb9d-4894-961f-e92f27bb6cb6
relation.isOrgUnitOfPublication.latestForDiscovery 85e04a04-fb9d-4894-961f-e92f27bb6cb6

Files