Parametric Trigger Signal Generation With Microcontroller and Fpga Based Architectures

dc.authorwosidlevent, vecdi/T-8847-2019
dc.authorwosidkazma, coşkun/AAP-7016-2020
dc.authorwosidAYDIN, Nizamettin/AAZ-6030-2020
dc.contributor.authorLevent, Vecdi Emre
dc.contributor.authorLevent, Vecdi Emre
dc.contributor.authorAydin, Nizamettin
dc.contributor.otherBilgisayar Mühendisliği Bölümü
dc.date.accessioned2025-01-11T13:01:32Z
dc.date.available2025-01-11T13:01:32Z
dc.date.issued2019
dc.departmentFenerbahçe Universityen_US
dc.department-temp[Kazma, Coskun; Aydin, Nizamettin] Yildiz Tekn Univ, Bilgisayar Muhendisligi Bolumu, Istanbul, Turkey; [Levent, Vecdi Emre] Fenerbahce Univ, Bilgisayar Muhendisligi Bolumu, Istanbul, Turkeyen_US
dc.description.abstractA new system to obtain information from the central nervous system has been developed. Our system consists of two main components. The first of these components is the machine, which is located on the index and middle finger tips, stimulating mechanoreceptors according to the test protocol. The other is a personal computer running a desktop software for the implementation of test protocols. The flow is as follows. The subjects are asked the question of the test protocol through the personal computer. The parameters are then transmitted to the embedded system board on the machine. The embedded system board takes step motors to apply the relevant test parameters. The desktop software expects the subject to answer the question using the right and/or the left mouse button of the computer mouse. After answering the relevant question, the test proceeds to the next step. According to the test protocol, the stimulation process of the mechanoreceptors located at the index and middle finger tips must start and terminate at the same time. From this perspective, the embedded system board with 3 18F46K22 PIC microcontrollers produces 2 square wave signals with different frequencies and amplitudes simultaneously. The embedded system card developed with the PIC microcontroller is also implemented on an FPGA. The system has also been tested on 24 blue- and white-collar employees and a significant result has been obtained.en_US
dc.description.woscitationindexConference Proceedings Citation Index - Science
dc.identifier.citation0
dc.identifier.doi[WOS-DOI-BELIRLENECEK-25]
dc.identifier.endpage144en_US
dc.identifier.isbn9781728139647
dc.identifier.scopusqualityN/A
dc.identifier.startpage140en_US
dc.identifier.urihttps://hdl.handle.net/20.500.14627/141
dc.identifier.wosWOS:000609879900027
dc.identifier.wosqualityN/A
dc.language.isotren_US
dc.publisherIeeeen_US
dc.relation.ispartof4th International Conference on Computer Science and Engineering (UBMK) -- SEP 11-15, 2019 -- Samsun, TURKEYen_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectParallel Square Wave Generationen_US
dc.subjectTactile Stimulatoren_US
dc.subjectFpgaen_US
dc.titleParametric Trigger Signal Generation With Microcontroller and Fpga Based Architecturesen_US
dc.typeConference Objecten_US
dspace.entity.typePublication
relation.isAuthorOfPublication8152bbc4-3dea-4808-b2b9-69399f11ec0b
relation.isAuthorOfPublication.latestForDiscovery8152bbc4-3dea-4808-b2b9-69399f11ec0b
relation.isOrgUnitOfPublication85e04a04-fb9d-4894-961f-e92f27bb6cb6
relation.isOrgUnitOfPublication.latestForDiscovery85e04a04-fb9d-4894-961f-e92f27bb6cb6

Files