Efficiency of Modulated and Dose Rate Altered Flattening Filter Free Beams in High Dose Per Fraction Radiotherapy Applications on the Survival of Prostate Cancer Cell Lines

dc.authorscopusid 36112858500
dc.authorscopusid 59270828900
dc.authorscopusid 36618855700
dc.authorscopusid 56690633700
dc.authorscopusid 57395411500
dc.authorscopusid 26433315600
dc.authorscopusid 8832725600
dc.contributor.author Öztürk, Ayşe
dc.contributor.author Şahin, Sevim
dc.contributor.author Güngör, G.
dc.contributor.author Karabey, A.U.
dc.contributor.author Şahin, S.
dc.contributor.author Duruksu, G.
dc.contributor.author Gündoğdu, Ö.
dc.contributor.other Mimarlık Bölümü
dc.contributor.other Elektrik-elektronik Mühendisliği Bölümü
dc.date.accessioned 2025-01-11T13:04:49Z
dc.date.available 2025-01-11T13:04:49Z
dc.date.issued 2021
dc.department Fenerbahçe University en_US
dc.department-temp Ceylan C., Department of Radiation Oncology, Istanbul Oncology Hospital, Istanbul, Turkey; Öztürk A., Center for Stem Cell and Gene Therapies Research and Practice, Faculty of Medicine, Kocaeli University, Kocaeli, Turkey; Güngör G., Department of Radiation Oncology, Acibadem University, Istanbul, Turkey; Karabey A.U., Department of Radiation Oncology, Kocaeli University, Kocaeli, Turkey; Şahin S., Vocational School of Health Services, Fenerbahce University, Istanbul, Turkey; Duruksu G., Center for Stem Cell and Gene Therapies Research and Practice, Faculty of Medicine, Kocaeli University, Kocaeli, Turkey; Yazır Y., Center for Stem Cell and Gene Therapies Research and Practice, Faculty of Medicine, Kocaeli University, Kocaeli, Turkey; Aksu G., Department of Radiation Oncology, Kocaeli University, Kocaeli, Turkey; Gündoğdu Ö., Deparment of Biomedical Engineering, Kocaeli Univetsity, Kocaeli, Turkey en_US
dc.description.abstract Background: The radiobiological effect of high dose rate FFF beams on the DU-145 cells was investigated with SBRT plans which have >10 Gy. Methods and Materials: To compare the radiobiological effect on DU-145 cell line four experiments designed: (1) the constant dose rate of 6 MV and 6 MV FFF with increased dose per pulse (2) the effect of dose per pulse while increasing instantaneous dose rate for 6 MV and 6 MV FFF, (3) the effect of increased average dose rate for 6 MV FFF and (4) the effect of protracted treatment time and modulation of 6 MV FFF beams. The survival fraction was counted with WST. Results: FF and FFF for 6 MV with same dose rate and treatment time has no effect on cell survival. Significant differences was observed on survival which were irradiated with 6 MV 600 MU/min and 6 MV FFF 1400 MU/min (p=0.024). There was no difference between 6 MV FFF 600 MU/min and 6 MV FFF 1400 MU/min for 10 Gy. The significant survival difference obtained for 20 Gy. The survival percentages for both 10 Gy and 20 Gy with Cyberknife were obtained higher than FFF. Conclusion: Our in-vitro study presented here show that higher dose rate and reduced treatment time might become a crucial factor for SBRT especially which has >10 Gy fraction dose. © 2021 Novin Medical Radiation Institute. All rights reserved. en_US
dc.description.sponsorship Kocaeli University Scientific Projects Office, (2018/64) en_US
dc.identifier.citation 0
dc.identifier.doi 10.52547/ijrr.19.4.13
dc.identifier.endpage 889 en_US
dc.identifier.issn 2322-3243
dc.identifier.issue 4 en_US
dc.identifier.scopus 2-s2.0-85122187273
dc.identifier.scopusquality Q4
dc.identifier.startpage 879 en_US
dc.identifier.uri https://doi.org/10.52547/ijrr.19.4.13
dc.identifier.uri https://hdl.handle.net/20.500.14627/402
dc.identifier.volume 19 en_US
dc.identifier.wosquality Q4
dc.language.iso en en_US
dc.publisher Novin Medical Radiation Institute en_US
dc.relation.ispartof International Journal of Radiation Research en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.scopus.citedbyCount 0
dc.subject Cell Survival en_US
dc.subject Flattening Filter Free en_US
dc.subject Radiobiology en_US
dc.subject Radiosurgery en_US
dc.title Efficiency of Modulated and Dose Rate Altered Flattening Filter Free Beams in High Dose Per Fraction Radiotherapy Applications on the Survival of Prostate Cancer Cell Lines en_US
dc.type Article en_US
dspace.entity.type Publication
relation.isAuthorOfPublication d9aec71e-bcf7-42bf-9ddb-7a0924db5815
relation.isAuthorOfPublication 137b9c99-3632-425b-a3e8-9dace6596145
relation.isAuthorOfPublication.latestForDiscovery d9aec71e-bcf7-42bf-9ddb-7a0924db5815
relation.isOrgUnitOfPublication da9f5bd2-8994-4c42-b975-9caa7f9ca0fa
relation.isOrgUnitOfPublication 573efe9a-4585-4e9f-9d6e-4231d0e477bb
relation.isOrgUnitOfPublication.latestForDiscovery da9f5bd2-8994-4c42-b975-9caa7f9ca0fa

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Efficiency_of_modulated_and_dose_rate_altered_flat (1).pdf
Size:
2.11 MB
Format:
Adobe Portable Document Format