dc.description.abstract Light exerts hormonal, circadian, and behavioral influences beyond its visual function, yet consensus is lacking on the optimal illuminance and correlated color temperature (CCT) for various workplace tasks within the scope of integrative lighting. This study investigates and compares five lighting scenarios-one dynamic and four static-in a real office environment to explore the balance between visual comfort, biological effectiveness, and user preference. The static scenarios comprised horizontal desk-plane illuminance and CCT settings of 500 lx at 4000 K, 1000 lx at 5500 K, 1250 lx at 4000 K, and 1500 lx at 5500 K, while the dynamic scenario varied between 500-1000 lx and 3500-5500 K at the desk plane over the day. Lighting conditions were assessed through objective measurements, melanopic equivalent daylight illuminance calculations, and subjective surveys over short- and long-term exposures. The study found that high illuminance and cool light enhanced alertness and energy, but participants preferred neutral light with elevated illuminance. The scenario with 1250 lx at 4000 K was most favored, providing an optimal balance between visual and nonvisual effects. These findings guide integrative lighting design to enhance office comfort, well-being, and productivity.
dc.description.sponsorship Yimath;ldimath;z Technical University Scientific Research Projects Coordination Unit [FDK-2019-3594]
dc.description.sponsorship This research was supported by the Yıldız Technical University Scientific Research Projects Coordination Unit under project number [FDK-2019-3594].
dc.identifier.doi 10.1080/15502724.2026.2671809
dc.identifier.issn 1550-2716
dc.identifier.issn 1550-2724
dc.identifier.uri https://hdl.handle.net/123456789/1575
dc.identifier.uri https://doi.org/10.1080/15502724.2026.2671809
dc.language.iso en
dc.publisher Taylor & Francis Inc
dc.rights info:eu-repo/semantics/closedAccess
dc.subject Static Lighting
dc.subject Dynamic Lighting
dc.subject Integrative Lighting
dc.subject Office Lighting
dc.subject Melanopic Illuminance
dc.title Comparison of Integrative Lighting Scenarios: Insights from an Office Field Study
dc.type Article
dspace.entity.type Publication
gdc.coar.access metadata only access
gdc.coar.type text::journal::journal article
gdc.description.department Fenerbahçe University
gdc.description.departmenttemp [Kaplan, Elif] Fenerbahce Univ, Fac Architecture & Design, Dept Interior Architecture & Environm Design, Istanbul, Turkiye; [Ozturk, Leyla Dokuzer] Yildiz Tech Univ, Fac Architecture, Dept Architecture, Istanbul, Turkiye
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
gdc.description.woscitationindex Science Citation Index Expanded
gdc.identifier.wos WOS:001776764900001
gdc.index.type WoS
relation.isAuthorOfPublication.latestForDiscovery 07418e9a-9d41-4e28-a2f9-bd226fdf4f81
relation.isOrgUnitOfPublication.latestForDiscovery ca7e1f00-cfa9-4a7f-928b-78cbb9b7575e

Files