Repository logoGCRIS
  • English
  • Türkçe
  • Русский
Log In
New user? Click here to register. Have you forgotten your password?
Home
Communities
Browse GCRIS
Entities
Overview
GCRIS Guide
  1. Home
  2. Browse by Author

Browsing by Author "Murias, Juan Manuel"

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • Loading...
    Thumbnail Image
    Article
    Verification Trials Can Create the Illusion of VO2max in Addition to Contributing to Its Confirmation
    (Wiley, 2026) Cabuk, Refik; Alp, Egemen; Murias, Juan Manuel; Karsten, Bettina
    This study examined whether constant-workload verification trials performed at intensities below, at, and above the ramp-incremental peak power output (PPO) contribute to confirming maximal oxygen uptake (VO2max). Fifteen trained to well-trained male cyclists (VO2max: 63.6 +/- 5.6 mL & centerdot;kg(-1)& centerdot;min(-1)) completed maximal ramp testing followed by seven randomized verification trials (80%-110% PPO at 5% intervals) on separate days. Differences in VO2 responses were analyzed using linear mixed-effects models. Effect size was calculated using Hedges' g. The peak VO2 attained during the verification trials was expressed relative to the ramp-derived VO2max and classified as lower (< 95%), within normal variability (95%-105%), or higher (> 105%). The peak VO2 values at 80%, 105%, and 110% PPO were significantly lower than ramp-derived VO2max (p < 0.05), whereas no significant differences were observed at 85%, 90%, and 95% PPO. Effect sizes were small at 85%-95% PPO (Hedges' g = 0.29-0.32), medium at 100%-105% PPO (Hedges' g = 0.63-0.66), and large at 80% and 110% PPO (Hedges' g = 1.21-1.34). Of 105 verification trials, 81 were within +/- 5% of ramp VO2max, 22 were lower (mainly at 80% and 110% PPO), and two exceeded ramp VO2max (at 85% and 95% PPO). Although verification trials did not meaningfully contribute to the verification of VO2max, trials performed at 85%-95% PPO provided the best chances of confirming VO2max in trained individuals. Interpretation of verification trials relative to ramp-derived PPO is protocol dependent, which may limit generalizability across different ramp designs.
Repository logo
Collections
  • Scopus Collection
  • WoS Collection
  • TrDizin Collection
  • PubMed Collection
Entities
  • Research Outputs
  • Organizations
  • Researchers
  • Projects
  • Awards
  • Equipments
  • Events
About
  • Contact
  • GCRIS
  • Research Ecosystems
  • Feedback
  • OAI-PMH

Powered by Research Ecosystems

  • Privacy policy
  • End User Agreement
  • Feedback